We're Your Well Pump, Water Heater & Water Softener Professionals!

 

* First Name * Last Name * Phone Need service for: Email  

Well Pump Keeps Running? No Pressure – but it’s Probably Your Well Pressure Tank

“It seems like our well pump is going without a break.”

 

If this sounds like your water system, there’s a professional term for it: “short cycling.” No sooner does the pump stop running, than it starts up again. It’s desperately trying to maintain pressure within the system.

 

Why? The well pressure tank, which stores water drawn from the well prior to use, has an issue. The exact issue depends on the type of water pressure tank.

 

Most likely it’s “waterlogging,” which happens in a bladder tank. These well pressure tanks, the most common model, store water in a bladder within their metal shells. Surrounding air pushes on the balloon, keeping the water under pressure.

 

All is well until the bladder springs a leak … and the air pocket fills with water. Bye-bye, water pressure.

 

Homeowners in Richwood, it’s time to replace the tank … which means a call to Kelly James Service, the well water pressure tank experts in Richwood. They’ll install a new pressure tank the same day, and stop your well pump’s endless short-cycling.

 

Air spitting from faucets? It’s another symptom of a broken bladder. If the problem isn’t already fatal, it soon will be.

 

Not all Richwood residences with well water systems have bladder tanks. Some use an air volume control tank, part of the well’s vertical in-ground pipe. The system employs bleeders, which allow a measured volume of water into the pipe. The water creates an air pocket, which generates pressure when the pump cycles to push in more water.

 

Problems begin when these bleeders become blocked over time, reducing the initial water level in the pipe. With less water, pressure in the system goes down. The pump cycles in an endless effort to provide additional water to sustain adequate pressure, and keep the system operating.

 

A third type of well water pressure tank is made of galvanized metal, which nessitates) that its internal air supply be manually replenished {each year. Typically found in older homes, these tanks eventually leak. Like an air volume control tank, the well pump operates near-constantly to maintain pressure as the internal water level drops.

 

Galvanized and air volume control tanks can also suffer from mineral accumulations. These constrain water flow from the tank into the home. Low water pressure results. Again, replacement is the only practical choice.

 

Richwood residents: Tired of hearing your well pump run nonstop? Let Kelly James Service bring back the peace – not to mention water pressure – that you appreciate. You’ll be amazed how short a time it takes them to stop your pump’s short-cycling.

Well Pump Keeps Running? Kelly James Service is your Well Pump Expert near Richwood, WI